Mimaki at PSI 2015

Mimaki Demonstrates the Power of Promotional Print at PSI 2015 Amsterdam, December 18, 2014 Mimaki is taking its European-wide Let’s Create… Together showcase to PSI in Düsseldorf, Germany, from January 7 to 9, 2015. The focus of the show is promotional products. Mimaki will be at booth 12B13 in the Technology Forum at the show, […]

What should i do when [ERROR 211 – INVERTER WRONG] is displayed?

Answer: This error may occur under the overload due to clogged air filter of the optional vacuum unit, or at the maximum vacuum strength volume of 65. 1. Turn off the main power supplies of the main unit and vacuum unit, and then remove and clean the air filter. Cleaning procedure ① Remove the air […]

What should I do to keep good print quality?

Answer: Please check the following contents. The following is an example of daily workflow. More details of each step are described on the next page. 1.Before printing ① Shake the white ink cartridge daily and reinsert it into the ink slot. [How to shake] Wear gloves and apply cloth to the insertion side as shown […]

What should i do when [Error511 Z origin detect] is displayed?

Answer: This error occurs when the table does not operate normally. 1. Make sure the table is moving up & down. 2. Check if there is strange noise around the table. 3. The weight of media must be 5kg or less (including jig) by specifications. Check that the weight of the media mounted on the […]

What should i do when [Error505 !WORK High] is displayed?

Answer: This error is displayed when the obstacle sensor detects an obstacle that can collide with the head. Check that the setting value of “MEDIA THICKNESS” or “HEAD GAP” is appropriate against the actual thickness of the media. In addition, check on the followings: ・Dust or garbage is not sticking to the surface of table […]

What should i do when [Error201 COMMAND] is displayed?

Answer: This error is displayed if data other than command data is received. 1. Reprint with different color profiles. 2. Check if there are some damages on the USB cable. [For UJF-3042HG] Check that the accompanying ferrite core is attached to USB. If not, attach it. 3. Replace the USB cable to other one.  ・Use […]

The display will be Local after each print, what should i do?

Answer: Please see the followings: 1. After completing printing, you can set whether to return to Local mode or to   remain in Remote mode. For how to set it, see   “OPERATION MANUAL” -> “Chapter 3” -> “Various settings” -> “Setting the work change”.   When [OFF] is set: Keeps Remote mode after printing. […]